List of parameters
Parameters
1-361
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Description: Sets the signal source for the feedback signal "adjustment value valid".
BI: p2662 = 1 signal
The adjustment value received via CI: p2660 is valid.
BI: p2662 = 0 signal
The adjustment value received via CI: p2660 is not valid.
Dependency: Refer to: r2526, p2660
Description: Sets the signal source for the feedback signal "clamping active for travel to fixed stop".
BI: p2663 = 1 signal
Clamping is active
BI: p2663 = 0 signal
Clamping is not active.
Dependency: Refer to: r2526
Note: The feedback signal from "terminals active" is, for the factory setting, dependent on the signal BO: r2526.8 (termi-
nals active when moving to a fixed stop).
Description: Displays the actual absolute position setpoint.
Dependency: Refer to: p2530
Note: As standard, the following BICO interconnection is established: CI: p2530 = r2665
Description: Displays the actual velocity setpoint.
Dependency: Refer to: p2531
Note: As standard, the following BICO interconnection is established: CI: p2531 = r2666
p2662 BI: EPOS adjustment value valid feedback signal / Adj val valid FS
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 3 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- - 2526.9
p2663 BI: EPOS clamping active feedback signal / Clamping active FS
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 3 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 3616
Min Max Factory setting
- - 2526.8
r2665 CO: EPOS position setpoint / s_set
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 1 Calculated: - Data type: Integer32
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 3635
Min Max Factory setting
- [LU] - [LU] - [LU]
r2666 CO: EPOS velocity setpoint / v_set
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 1 Calculated: - Data type: Integer32
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 3635
Min Max Factory setting
- [1000 LU/min] - [1000 LU/min] - [1000 LU/min]