Siemens SINAMICS G120D - r2667 CO: EPOS backlash compensation value; Backlash value; r2669 CO: EPOS actual operating mode; Op mode act; r2670.0...15 CO;BO: EPOS status word active traversing block; ZSW act trav_block

Siemens SINAMICS G120D
910 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
List of parameters
1-362
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Description: Displays the actual effective value for backlash compensation.
Dependency: Refer to: p2516
Note: As standard, the following BICO interconnection is established: CI: p2516 = r2667
Description: Displays the actual active operating mode.
Value = 00 hex -> no operating mode active
Value = 01 hex -> jogging active
Value = 02 hex -> search for reference active
Value = 04 hex -> traversing blocks active
Value = 08 hex -> Positioning for direct setpoint input/MDI active
Value = 10 hex -> Setting-up for direct setpoint input/MDI active
Value = 20 hex -> flying referencing active
Dependency: Refer to: p2589, p2590, p2595, p2631, p2647, p2653
Description: Displays the status word for the active traversing block.
r2670.0: Active traversing block, bit 0
...
r2670.5: Active traversing block, bit 5
r2670.15: MDI active
Dependency: Refer to: p2631, p2647
Note: Re bit 00 ... 05:
Displays the active traversing block in the traversing blocks operating mode.
Re bit 15:
For a 1 signal, the operating mode - direct setpoint input/MDI - is active
r2667 CO: EPOS backlash compensation value / Backlash value
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 1 Calculated: - Data type: Integer32
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 3635
Min Max Factory setting
- [LU] - [LU] - [LU]
r2669 CO: EPOS actual operating mode / Op mode act
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 1 Calculated: - Data type: Integer32
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 3625, 3630
Min Max Factory setting
- - -
r2670.0...15 CO/BO: EPOS status word active traversing block / ZSW act trav_block
CU250D-2_DP_F
CU250D-2_PN_F
Access level: 1 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 3615, 3625, 3650
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Active traversing block bit 0 Active Not active -
01 Active traversing block bit 1 Active Not active -
02 Active traversing block bit 2 Active Not active -
03 Active traversing block bit 3 Active Not active -
15 MDI active Active Not active -