Basic positioner (EPOS)
Function diagrams
2-673
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Fig. 2-84 3618 – Direct setpoint specification / MDI mode, dynamic values
- 3618 -
Function diagram
87654321
fp_3618_97_55.vsd
Basic positioner (EPOS)
G120D CU250D-2
12.12.2012 V4.6
Direct setpoint input/MDI mode, dynamic values
[3620.1]p2690
p2691
p2692
p2693
[3620.1]
[3620.1]
[3620.1]
100 %
0.1 %
100 %
0.1 %
1
MDI s_set
(2690[0])
p2642
MDI v_set
(2691[0])
p2643
MDI a_over
(2692[0])
p2644
MDI -a_over
(2693[0])
p2645
Pos fixed value
-2147482648 ... 2147482647 [LU]
p2690 (0)
v fixed value
1 ... 40000000 [1000 LU/min]
p2691 (600)
a_over fixed val
0.100 ... 100.000 [%]
p2692 (100.000)
-a_over fixed val
0.100 ... 100.000 [%]
p2693 (100.000)