Siemens SINAMICS G120D - p20133 CI: AVA 1 input X; AVA 1 input X; r20134 CO: AVA 1 output Y; AVA 1 output Y; r20135 BO: AVA 1 input negative SN; AVA 1 input neg SN; p20136 AVA 1 run-time group; AVA 1 RTG

Siemens SINAMICS G120D
910 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameters
1-489
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Note: The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
Description: Sets the signal source of the input quantity X of instance AVA 1 of the absolute value generator with sign evalua-
tion.
Description: Display parameter for output quantity Y of instance AVA 1 of the absolute value generator with sign evaluation.
Description: Display parameter for signal SN that the input quantity X of instance AVA 1 of the absolute value generator with
sign evaluation is negative.
X < 0.0 => SN = 1
Description: Setting parameter for the run-time group in which instance AVA 1 of the absolute value generator with sign evalua-
tion is to be called.
Value: 5: Run-time group 5
6: Run-time group 6
9999: Do not calculate
p20133 CI: AVA 1 input X / AVA 1 input X
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: U32 / FloatingPoint32
Can be changed: T Scaling: PERCENT Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7224
Min Max Factory setting
- - 0
r20134 CO: AVA 1 output Y / AVA 1 output Y
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: PERCENT Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7224
Min Max Factory setting
- - -
r20135 BO: AVA 1 input negative SN / AVA 1 input neg SN
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7224
Min Max Factory setting
- - -
p20136 AVA 1 run-time group / AVA 1 RTG
CU240D-2_DP
CU240D-2_DP_F
CU240D-2_PN
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: Integer16
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7224
Min Max Factory setting
5 9999 9999