List of parameters
Parameters
1-89
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Description: Displays the encoder status word Gn_ZSW according to PROFIdrive.
Index: [0] = Encoder 1
[1] = Encoder 2
[2] = Encoder 3
Notice: Information on Gn_STW/Gn_ZSW can, e.g. be found in the following literature:
SINAMICS S120 Function Manual Drive Functions
Note: Re bit 14:
Displays the acknowledgement for "activate parking encoder" (Gn_STW.14 = 1) or encoder position actual value
(Gn_XIST1) invalid.
Re bit 14, 15:
r0481.14 = 1 and r0481.15 = 0 can have one of the following causes:
- the encoder is parked.
- the encoder is de-activated.
- the encoder is being commissioned.
- no parameterized encoder available.
- encoder data set is being changed over.
r0481.14 = 1 and r0481.15 = 1 has the following significance:
An encoder error has occurred and the encoder position actual value (Gn_XIST1) is invalid.
Description: Displays the encoder actual position value Gn_XIST1 according to PROFIdrive.
Index: [0] = Encoder 1
[1] = Encoder 2
[2] = Encoder 3
Note: - this value is reset if necessary when the "parking encoder" (r0481.14) function is de-selected.
- in this value, the measuring gear (p0432, p0433) is only taken into account when the position tracking is activated
(p0411.0 = 1).
r0481[0...2] CO: Encoder status word Gn_ZSW / Enc Gn_ZSW
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 4010, 4704, 4730,
4750
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Function 1 active Yes No -
01 Function 2 active Yes No -
02 Function 3 active Yes No -
03 Function 4 active Yes No -
04 Value 1 Displayed in r0483 Not present -
05 Value 2 Displayed in r0483 Not present -
06 Value 3 Displayed in r0483 Not present -
07 Value 4 Displayed in r0483 Not present -
08 Measuring probe 1 deflected Yes No -
09 Measuring probe 2 deflected Yes No -
11 Encoder fault acknowledge active Yes No 9676
13 Absolute value cyclically Displayed in r0483 No -
14 Parking encoder active Yes No -
15 Encoder fault Displayed in r0483 None -
r0482[0...2] CO: Encoder actual position value Gn_XIST1 / Enc Gn_XIST1
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 1580, 1680, 4704,
4735, 4740, 4750
Min Max Factory setting
- - -