Safety Integrated Basic Functions
Function diagrams
2-635
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Fig. 2-50 2800 – Parameter manager
- 2800 -
Function diagram
87654321
fp_2800_97_58.vsd
Safety Integrated Basic Functions
SINAMICS G120D
12.12.2012 V4.6
Parameter Manager
x
y
=
=
SET
y = x
=
<1>
=
&
&
SI act chksm P1
r9798
Changing safety parameters
Resetting safety parameters
Safety parameterizing
enable
Checksum check
for safety
parameters
Safety parameters can
be reset to the factory
settings via p0970,
p3900.
Safety parameters
can be changed
Safety-IBN-Modus
[2802.1][2810.4]
--> STO anwählen
Effective password
Enter password
Safety Integrated commissioning
p0010 = 95
Safety parameters
are valid.
p0010 unequal 95
Exit safety
commissioning
mode
Inhibit safety functions
Safety Integrated Basic Functions
SI password inp
p9761
SI setp_chksm P1
p9799
SI act_chksm P2
r9898
SI setp_chksm P2
p9899
SI enable fct P2
p9801 = 0
[2810.3]
SI password new
p9762
SI ackn password
p9763
SI enable fct P1
p9601 = 0
SI Mtn act CRC P1
r9728
SI Mtn setp CRC P1
p9729
SI Mtn act CRC P2
r9398
SI Mtn setp CRC P2
p9399
[2810.3]
SI Mtn enable CU
p9501 = 0
SI Mtn enable P2
p9301 = 0
[2810.3]
[2810.3]
<2>
<2>
<2> <2>
<2><2>
Safety Integrated Extended Functions<2>
<1>
<1>
<1> <1>
<1> <1>