List of parameters
Parameters
1-97
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Description: Sets the edge to evaluate the measuring probe signal for speed actual value measurement.
0: 0/1 edge
1: 1/0 edge
Dependency: Refer to: p0580
Description: Sets the number of pulses per revolution (e.g. for disks with holes).
Description: Sets the maximum measuring time for the measuring probe.
If a new pulse is not received before the maximum measuring time has expired, then the speed actual value in
r0586 is set to zero. This timer is re-started with the next pulse.
Dependency: Refer to: r0586
Description: Sets the BERO gear factor.
The measured speed is multiplied by the BERO gear factor and is displayed in r0586.
Description: Displays the speed actual value measured using the BERO.
Dependency: Refer to: p0580, p0583
Note: For p0580 = 0 (no measuring probe), a value of zero is displayed here.
p0581 Measuring probe edge / MT edge
Access level: 3 Calculated: - Data type: Integer16
Can be changed: U, T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
0 1 0
p0582 Measuring probe pulses per revolution / MT pulses per rev
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: U, T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
1 12 1
p0583 Measuring probe maximum measuring time / MT t_meas max
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: U, T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
0.040 [s] 10.000 [s] 10.000 [s]
p0585 Measuring probe gear factor / Probe gear factor
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: U, T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
0.00000 1000.00000 1.00000
r0586 CO: Measuring probe speed actual value / MT n_act
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: p2000 Dyn. index: -
Units group: 3_1 Unit selection: p0505 Func. diagram: -
Min Max Factory setting
- [rpm] - [rpm] - [rpm]