Siemens SINAMICS G120D - p4684[0...n] Zero mark monitoring tolerance window alarm threshold negative; ZM tol A_thr neg; p4685[0...n] Speed actual value mean value generation; n_act mean val; p4686[0...n] Zero mark minimum length; ZM min length; p4688[0...2] CO: Zero mark monitoring differential pulse count; ZM diff_pulse qty

Siemens SINAMICS G120D
910 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameters
1-385
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Description: Sets the negative tolerance window in encoder pulses for limit 2 for the zero mark monitoring.
If the zero mark deviation is higher than the tolerance set in p4681 and p4682 and fault F3x131 is re-parameterized
to alarm (A) or no message (N), the accumulator p4688 is compared with this parameter and, if applicable, alarm
A3x422 is output for 5 seconds.
Dependency: Refer to: p0437, p4683, p4688
Refer to: F31131, A31422
Note: Zero mark monitoring is activated by setting p0437.2 = 1 (position actual value correction).
For a set value = -100001, the negated value of p4683 is effective.
Description: Sets the number of current controller clock cycles for mean value generation of the speed actual value.
Note: Value = 0, 1: No mean value generation.
Higher values also mean higher dead times for the speed actual value.
Description: Sets the minimum length for the zero mark.
Dependency: Refer to: p0425, p0437
Note: The value for the minimum length of the zero mark must be set less than p0425.
The parameter is activated using p0437.1 = 1 (zero mark edge detection).
Description: Displays the number of differential pulses for the zero mark monitoring that have accumulated.
If fault F3x131 is re-parameterized to alarm (A) or no message (N), the encoder pulses which have not been cor-
rected are added to the accumulator (p4688).
Index: [0] = Encoder 1
[1] = Encoder 2
[2] = Encoder 3
Dependency: Refer to: p4681, p4682, p4683, p4684
Note: The display can only be reset to zero.
p4684[0...n] Zero mark monitoring tolerance window alarm threshold negative / ZM tol A_thr neg
Access level: 3 Calculated: - Data type: Integer32
Can be changed: C(4) Scaling: - Dyn. index: EDS, p0140
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
-100001 0 -100001
p4685[0...n] Speed actual value mean value generation / n_act mean val
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: C(4) Scaling: - Dyn. index: EDS, p0140
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
0 20 0
p4686[0...n] Zero mark minimum length / ZM min length
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: C(4) Scaling: - Dyn. index: EDS, p0140
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
0 10 1
p4688[0...2] CO: Zero mark monitoring differential pulse count / ZM diff_pulse qty
Access level: 3 Calculated: - Data type: Integer32
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
-2147483648 2147483647 0