EasyManuals Logo

ST STM32F101xx User Manual

ST STM32F101xx
1096 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #447 background imageLoading...
Page #447 background image
RM0008 General-purpose timers (TIM9 to TIM14)
Doc ID 13902 Rev 12 447/1096
Input capture mode
Bits 15:8 Reserved
Bits 7:4 IC1F: Input capture 1 filter
This bit-field defines the frequency used to sample TI1 input and the length of the digital filter
applied to TI1. The digital filter is made of an event counter in which N events are needed to
validate a transition on the output:
0000: No filter, sampling is done at f
DTS
0001: f
SAMPLING
=f
CK_INT
, N=2
0010: f
SAMPLING
=f
CK_INT
, N=4
0011: f
SAMPLING
=f
CK_INT
, N=8
0100: f
SAMPLING
=f
DTS
/2, N=6
0101: f
SAMPLING
=f
DTS
/2, N=8
0110: f
SAMPLING
=f
DTS
/4, N=6
0111: f
SAMPLING
=f
DTS
/4, N=8
1000: f
SAMPLING
=f
DTS
/8, N=6
1001: f
SAMPLING
=f
DTS
/8, N=8
1010: f
SAMPLING
=f
DTS
/16, N=5
1011: f
SAMPLING
=f
DTS
/16, N=6
1100: f
SAMPLING
=f
DTS
/16, N=8
1101: f
SAMPLING
=f
DTS
/32, N=5
1110: f
SAMPLING
=f
DTS
/32, N=6
1111: f
SAMPLING
=f
DTS
/32, N=8
Note: In current silicon revision, f
DTS
is replaced in the formula by CK_INT when ICxF[3:0]= 1,
2 or 3.
Bits 3:2 IC1PSC: Input capture 1 prescaler
This bit-field defines the ratio of the prescaler acting on CC1 input (IC1).
The prescaler is reset as soon as CC1E=’0’ (TIMx_CCER register).
00: no prescaler, capture is done each time an edge is detected on the capture input
01: capture is done once every 2 events
10: capture is done once every 4 events
11: capture is done once every 8 events
Bits 1:0 CC1S: Capture/Compare 1 selection
This bit-field defines the direction of the channel (input/output) as well as the used input.
00: CC1 channel is configured as output
01: CC1 channel is configured as input, IC1 is mapped on TI1
10: CC1 channel is configured as input, IC1 is mapped on TI2
11: CC1 channel is configured as input, IC1 is mapped on TRC. This mode is working only if
an internal trigger input is selected through TS bit (TIMx_SMCR register)
Note: CC1S bits are writable only when the channel is OFF (CC1E = 0 in TIMx_CCER).