iPECS UCP
Feature Description and Operation Manual Issue 1.3
167
5) LCR Access Mode 12 (M12) – Direct CO, Loop and Internal LCR access
are active, seize CO line according to the LCR attributes.
6) LCR Access Mode 13 (M13) – Direct CO, Loop and Internal LCR access
are active, seize CO line according to the station attributes.
2. Multiple Leading Digit Tables can be configured for each station and outside Line.
3. Leading digit entries may be duplicated in the Leading Digit Table. Using a
different “LDT Index” will make each entry unique. The system will use the lowest
matching entry.
4. When Direct CO LCR is used on an ISDN line, an ISDN information message with
the Called party Info Element, which includes only the numbering plan and
numbering type, is sent to the ISDN to maintain the ISDN connection while the
user finishes dialing and the system modifies the digits.
5. For Direct CO LCR, the number of digits for the LDT Table should be programmed
considering the dial-tone time-out of the network.
6. Since an outside Line is connected, Direct CO LCR does not support the
Alternative DMT index, which allows the system to select a second or alternative
outside Line to place the call.
7. If the LCR CO group is not assigned, the system will not seize an outside Line and
will place internal call.
8. If the LCR CO group is assigned as the unused group, the system will seize an
outside Line according to the station attributes.
9. The system selects the LDT main index from {LDT Table Index} of Common
Attributes(111). and the system compares the dialed data with {Compared Digits}
of sub index tables which have same {LDT Zone number} with {LDT Zone number}
of Common Attributes(111).
Programming
STATION DATA Common Attributes LDT Table Index