iPECS UCP
Feature Description and Operation Manual Issue 1.3
380
6. ATTENDANTS
6.1 Active CPU (UCP) Display
Description
When the system is equipped for CPU Redundancy, the System Attendant can determine
and change the active and standby CPU.
Operation
System Attendant
[TRANS/PGM] + {FLEX} + [TRANS/PGM] + “078” + [HOLD/SAVE]
To assign a Flex button for Active CPU Display
1. Press the [TRANS/PGM] button.
To view the active UCP
2. Dial “078” the Active CPU Display code, the active CPU is displayed.
Or,
1. Press the {Active CPU Display} Flex button to display the active CPU.
1. Press the [TRANS/PGM] button.
To Change Standby UCP to Active UCP
2. Dial “078” the Active CPU Display code.
3. Dial “#” to change the standby iPECS UCP module to active.
Conditions
1. The system must be equipped with and properly programmed in Redundancy Data
for Redundant Processor operation and for the Attendant to display or change the
active UCP.
2. The System Attendant can assign a Flex button to indicate when the back-up
iPECS UCP module is active. When assigned, the LED of the Flex button will turn
ON indicating the back-up UCP is active.
Programming
REDUNDANCY DATA
Redundancy Attributes CPU Redundancy Usage
Related Features
Redundant System Processor