iPECS UCP
Feature Description and Operation Manual Issue 1.3
123
the call is disconnected and the appropriate circuits returned to idle.
Operation
Conditions
Hold Recall operation is automatic.
1. Separate timers are assigned for the various types of hold: System, Exclusive,
Transfer, Call Park, etc.
2. If the I-Hold timer is set to zero, the station will not receive recall. If the Attendant
Recall timer is set to zero, the Attendant will not receive recall.
3. If the specific Hold timer is set to zero, recall is disabled.
4. In case of Private Lines, recall ring is served only to the station that held the call
and will recall until answered or abandoned.
Programming
SYSTEM DATA System Attributes Hold Preference
System Attributes Attendant Recall Timer, Exclusive Hold
Recall Timer, I-Hold Recall Timer, System Hold Recall
Timer, Transfer Recall Timer
Related Features
Call Transfer, Line
Exclusive Hold
System Hold
Hardware
2.42.4 Exclusive Hold
Description
Outside lines may be placed in a waiting state such that other stations in the system are
unable to access the line. Only the station placing the line on Exclusive Hold can access the
held line.
If the call remains on hold at expiration of the Exclusive Hold Recall Timer, normal Hold
Recall will apply.