Feature Description and Operation Manual Issue 1.3
303
4.5 CO Line Ring Detect
Description
The system incorporates timers for Ring-On and Ring-Off durations to assure proper alerting.
When the duration of the ring signal exceeds the Ring-on timer, alerting will start. When the
ring is not present for a period exceeding the Ring-off timer, alerting will stop. This allows the
system Ring cycle detection to be matched to various PBX and carrier systems.
Operation
System
Conditions
Operation of Ring detect is automatic.
1. Ring-On and Ring-Off are assigned on a system basis.
2. The CO Ring Detect is applied to analog CO Lines only.
Programming
SYSTEM DATA
System Timers
CO Ring On Timer, CO Ring Off Timer
Related Features
Hardware
Analog CO Line