2.79 System Alarm Notification Control
Description
The system has several fault alarms that can be enabled or disabled. When enabled, a
Station within each Zone can be assigned to receive a notification of the alarm event. A
second station in the Zone may be notified of Emergency calls from the zone. Alarms that
can be enabled are:
Emergency call placed
Digital (BRI or E1/PRI) Line fault
SIP Trunk/Extension registration fault.
Assigned stations receive the fault Alarm Signal, a single tone burst repeated at 1-minute
intervals or a continuous tone. The Alarm Signal may be terminated at the phone by dialing
the Alarm Reset code or, if assigned, pressing the {ALARM RESET} button. To rearm the
Alarm function, the alarm condition must be cleared and the Alarm signal terminated.
When enabled, the Emergency call or fault event causes an alarm ring at the Station. The
Station can terminate the fault Alarm notification
Operation
System
iPECS IP & LDP Phones
At detection of fault or Emergency Call, the Alarm signal is sent to assigned stations.
[TRANS/PGM] + {FLEX} + “565” + [HOLD/SAVE]
To assign a Flex button as an {ALARM RESET} button to terminate the Alarm Signal
1. Dial the Flex Numbering Plan code “565”, confirmation tone is received and the
Alarm Signal is terminated. If the alarm condition is cleared, the system will
automatically rearm the alarm monitoring.
To terminate an Alarm Signal, while idle
Or,
Press the {ALARM RESET} button.
Conditions
1. The station must terminate the Alarm signal at their phone. However, a Main
Attendant can terminate the Alarm signal at the System Attendant.
2. When no station is assigned to receive an Alarm, the System Attendant will
receive the notification.
3. For Digital Line and SIP registration faults, the station in the Zone associated with
first Line of the BRI/E1/PRI interface or SIP channel receives the alarm signal.
4. The notification process for Emergency calls follows the Zone from which the call