iPECS UCP
Feature Description and Operation Manual Issue 1.3
384
6.5 Attendant Recall
Description
Unanswered or abandoned outside calls that remain unanswered for the Hold or Transfer
Hold timer, as appropriate, will recall the station placing the call on hold. If the call remains
unanswered for the assigned Recall time, the first available Attendant will also receive recall.
The Attendant and station will receive the recall signal for the Attendant Recall Timer period
after which the system will disconnect and return the outside Line to idle.
Operation
System
Conditions
Attendant recall operation is automatic.
Programming
SYSTEM DATA System Timers Attendant Recall Timer, I-Hold Recall
Timer
Related Features
Hold
Hold Recall
Call Transfer
Hardware
iPECS IP or LDP Multi-button Phone, a 24-button phone is
recommended