9
4. Dial Authorization Code (1 to 12 digits).
5. Momentarily press the Hook-switch, receive confirmation tone.
1. Dial the station number for the Station Authorization code or, for a System
Authorization Code, dial “*” or “*” and the Authorization table index.
To enter your Authorization Code when second dial tone is received
2. Dial the corresponding Authorization Code.
3. Momentarily press the Hook-switch.
4. Place your call as normal.
DISA
1. Dial the station number for a Station Authorization code or, for a System code, “*”
or“*” and the Authorization table index.
To enter an Authorization Code when second dial tone is received
2. Dial the corresponding Authorization Code.
3. Place call as normal.
System Attendant
1. Press the [TRANS/PGM] button.
To assign an Authorization Code
2. Dial Attendant Station Program code 031”.
3. Dial the Station number for a Station code or, for system code, “*” or “*” and the
Authorization table index.
4. Dial the corresponding Authorization Code.
5. Press the [HOLD/SAVE] button.
Conditions
1. When an outside DISA Line is marked for Authorization Code entry, the caller will
hear fast busy tone and must input a valid Authorization Code to continue. In case
of an entry error, the caller may retry entry of the code.
2. A DISA caller must enter a valid code within the number of attempts assigned as
the FAC(Forced Account Code) Retry Count. The station, if enabled, is placed in
COS (Class of Service) 7 after repeated failure attempts.
3. A user may enter an Authorization Code from any station to place an outside call
using Walking COS (Class of Service).
4. The system provides memory for up to 5200 Authorization codes, 2400 for station
codes and the remaining 2800 are system codes.
5. Outside Line groups may be configured to require entry of a valid Authorization
Code for access. In this case, a second dial tone is provided when the Line group
is accessed. If the code entered is invalid, error tone is returned and the user must
enter a valid code within the FAC Retry Count.
6. If the Check Password option is enabled in the LCR database, when dialed digits
match the LDT Table digits, the system will send second dial tone to request that
you input a valid Authorization code.
7. An Authorization code may include any dial pad digit except “*” and “#”.
8. Duplicate or conflicting System Authorization codes are not allowed when using

Table of Contents