309
timer expires or disconnect supervision is received. A disconnect warning tone is
provided 15 seconds prior to disconnect.
6. If a DISA caller encounters a system All Lines Busy, busy tone is received for 5
seconds before ICM Dial tone is again presented and the DISA caller may try
another call.
7. LEDs associated with the DISA Line appearance will provide normal status
indications at all stations except the Attendants. The LED for the Line at an
Attendant will flutter at 240 ipm when busy.
8. An iPECS IP or LDP Phone user can only receive a DISA call with an available
DISA Line appearance button.
Programming
CO LINE DATA Common Attributes DISA Account Code, DISA CO Access
DISA Service Attributes
SYSTEM DATA System Attributes DISA Retry Count
DISA COS (Class of Service)
DID/DISA Destination
System Timers DID/DISA No Answer Timer, Unsupervised
Conference Timer
TABLES DATA CCR Table
Auto Ring Mode Table
Related Features
Day/Night/Timed/Scenario Ring Mode
Dialing Restrictions
Authorization Codes (Password)
Unsupervised Conference
Integrated Auto Attendant/Voice Mail
Auto Service Mode Control
Hardware

Table of Contents

Other manuals for iPECS UCP