iPECS UCP
Feature Description and Operation Manual Issue 1.3
342
For Internal” respectively.
Web
[Call Wait] = the following options (PGM113: Call Wait )
To activate/deactivate call wait
- OFF: Deactivate Call wait for all calls
- For External/Internal: Activate Call wait for External & Internal calls
- For External: Activate Call wait for External call
- For Internal: Activate call wait for Internal call
Web admin: [Station Data] => [Flexible buttons] => select ‘U-Loop’ Type and click [SAVE]
button.
To assign a {U-Loop} button
Keyset : [PGM] + flexible button + Call-coverage numbering plan + My station number.
- Example) 671001 ('67' is call-coverage feature code, '1001' is my station number).
1. One Unified-LOOP(U-LOOP) button can keep one incoming/making/talking/held
internal/external call.
Call Wait Flow
2. An incoming call is acknowledged to be waited if there is an idle Unified-LOOP(U-
LOOP) button. First call to a station is acknowledged even without an idle button.
From second call, there need to be an idle U-LOOP or Station/CO(Grp.)/(CO)LOOP
button to accept the incoming call without reject it to ‘busy’.
3. To make a call, user can dial internal or external number with or without press of the
button.
If user presses a button to make a call then the button will be used for the call.
If user does not press a button then an idle button is automatically seized for the call.
Make of internal call: [button] + dial station number
Make of external call: [button] + co access code + external number
4. Auto-Hold: a talking in a button is automatically sent to being held when press the
other button. Station Data > Common Attributes(111) > Automatic Hold.
5. Auto-Transfer: can transfer a talking call to a new making call by press idle button to
make a call (ex. Operation: user is talking a call => press an empty U-LOOP button
and make a call => complete the transfer by on-hook). Station Data > Common
Attributes(111) > Auto Transfer By Button.
1. Audible Muted Ring (Continuous/One-Burst/Silence by PGM111 Station Data
Programming > “Off-Hook Ring Type”.
Call Waite Indication
2. LCD Display
A. Display Caller Name & Number of Waiting Calls
B. Sequential Display : Talking Call => 1
st
waiting call (for 6 seconds) => 2
nd
waiting
call (for 6 seconds) => … => back to talking call if there is no more waiting call
3. LED Flashing
A. Talking/Making : Green Steady
B. Held : Green Normal-Flash
C. Held Recall : Green Fast-Flash, or Red Fast-Flash to distinguish from 1
st
waiting’
Red Normal-Flash
D. Incoming Waiting :