iPECS UCP
Feature Description and Operation Manual Issue 1.3
43
no tone or answer is detected within the Tone
Detect time.
ACNR Retry Count Count determines the number of times system will
attempt the call before ACNR is automatically
cancelled.
2. The call will be placed on the same outside Line as originally used. If the Line is
busy, an available Line in the same Line group will be seized.
3. The ACNR Retry Counter decrements by one when the system completes the
dialed number.
4. When the ACNR Pause Timer expires, if the station is in a busy state, the ACNR
Delay Timer is invoked.
5. Upon completion of dialing, the system will monitor the call for progress signals.
6. To preserve ACNR feature in the activate state, SLT users must stay in the Off-
hook state.
7. While in the ACNR dialing or waiting state, if the SLT user goes On-hook, SLT
ACNR is deactivated, automatically.
8. While ACNR is active for a SLT, the SLT user cannot receive or place a call.
Programming
SYSTEM ID &
Flexible Numbering Plan SLT ACNR
SYSTEM DATA
System Timers ACNR Delay Timer, ACNR Pause Timer,