Appendix N Trouble shooting and FAQ
N-5
N.4. LaunchPad
Problem (P) Possible cause Confirmation item
[Select Terminal] screen is displayed
after starting LaunchPad
and cannot
connect with main unit of
JUE-501/JUE-251.
Cable is not connected. Check that PC is connected to the main unit with Ethernet cable firmly.
Although the setting of the TCP/IP of the PC is
set to “Automatic access”, the PC could not
access the IP from the DHCP server.
Before starting the PC, check that the cable between the main unit and the
PC is connected correctly. If the PC has been started not connected to the
main unit, restart the PC after hooking up the main unit.
TCP/IP is not set.
C
heck that the network IP that is set in the PC matches the IP set in the main
unit.
Verify
that the subnet mask, default gateway, and priority DNS server that
are set in the PC match those set in the main unit.
The local area connection of the PC is
disabled. (Win2000 or later)
Check that the local area connection is set to ‘enable’ in the property
specification of the local area connection.
The local area connection of the PC is a bridge
connection.
Delete the bridge by clicking the right mouse button on the icon of the local
area connection.
[CIF_0010] error is generated on the
LaunchPad and the connection
between the LaunchPad and main unit
is lost.
Ethernet connection is abnormal Execute [Search for terminal] by LaunchPad and connect with main unit
again.