Lantronix SISPM1040-xxxx-L3 Web User Guide
33856 Rev. A https://www.lantronix.com/ 252
Logging: Specify the logging operation of this port. Notice that the logging message doesn't include the 4 bytes
CRC. The allowed values are:
Enabled: Frames received on the port are stored in the System Log.
Disabled: Frames received on the port are not logged. The default value is "Disabled".
Note: The logging feature only works when the packet length is less than 1518 (without VLAN tags) and the
System Log memory size and logging rate is limited.
Shutdown: Specify the port shut down operation of this port. The allowed values are:
Enabled: If a frame is received on the port, the port will be disabled.
Disabled: Port shut down is disabled. The default value is "Disabled".
Note: The shutdown feature only works when the packet length is less than 1518(without VLAN tags).
State: Specify the port state of this port. The allowed values are:
Enabled: To reopen ports by changing the volatile port configuration of the ACL user module.
Disabled: To close ports by changing the volatile port configuration of the ACL user module. The default
is "Enabled".
Counter: Counts the number of frames that match this ACE.
Buttons
Apply: Click to save changes.
Reset: Click to undo any changes made locally and revert to previously saved values.
Refresh: Click to refresh the page; any changes made locally will be undone.
Clear: Click to clear the counters.