Lantronix SISPM1040-xxxx-L3 Web User Guide
33856 Rev. A https://www.lantronix.com/ 473
DMS Troubleshooting
Problem: The switch lists itself as the only device in Topology View of DMS.
Problem: In DMS, the Local image shows the IP address of another switch.
Description: The switch is listed as only device in DMS Topology View in DMS; all devices are listed in DMS
device list. This is usually because the switch's gateway is not configured appropriately.
Resolution: An IP Route must be configured manually. For example, a switch IP address of 192.168.1.77 should
have the following IP route configured: ip route 0.0.0.0 0.0.0.0 192.168.1.x. Without the IP route configured, you
may be unable to view all devices on the network in DMS.
1. Go to DMS > Management > DMS Mode to check if the controller IP is correct.
2. Verify that the gateway of this switch is correctly configured.
3. Verify that all connected devices are displayed in DMS Topology View.
Problem: DMS Connectivity diagnostics fails to ICMP reachable device.
Description: DMS displays a device which is reachable via ICMP ping as failing the connection status in
diagnostics. Cable status displays as OK.
Resolution: Contact Technical Support.
Problem: DMS will discover the device type, name and model of some cameras and hosts but others are
displayed as Unknown.
Description: When a device is detected by DMS, the device’s information (such as type, model name…etc.) can
be recognized via LLDP (e.g. Switch), UPnP (e.g. AP), ONVIF (e.g. IP cam), NBNS (e.g. PC) packets if the
device supports these protocols. So if the device display as Unknown, that means this device do not issue above
mentioned protocol for DMS to recognize.
Resolution: You can manually assign and configure the device type and name for the unknown devices. See the
Topology View > Dashboard or the Topology View section.
Message: This page can’t load Google Maps correctly. See DMS > Graphical Monitoring > Map View on page
463 above.
For More DMS Information
See the online DMS Video.
See the online DMS Overview.

Table of Contents

Other manuals for Lantronix SISPM1040 L3 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lantronix SISPM1040 L3 Series and is the answer not in the manual?

Lantronix SISPM1040 L3 Series Specifications

General IconGeneral
BrandLantronix
ModelSISPM1040 L3 Series
CategorySwitch
LanguageEnglish

Related product manuals