Diagnostics > sFlow > Statistics
This page shows receiver and per-port sFlow statistics.
Receiver Statistics
Owner: This field shows the current owner of the sFlow configuration. It assumes one of three values as follows:
• If sFlow is currently unconfigured/unclaimed, Owner contains <none>.
• If sFlow is currently configured through Web or CLI, Owner contains <Configured through local
management>.
• If sFlow is currently configured through SNMP, Owner contains a string identifying the sFlow receiver.
IP Address/Hostname: The IP address or hostname of the sFlow receiver.
Timeout: The number of seconds remaining before sampling stops and the current sFlow owner is released.
Tx Successes: The number of UDP datagrams successfully sent to the sFlow receiver.
Tx Errors: The number of UDP datagrams that has failed transmission. The most common source of errors is
invalid sFlow receiver IP/hostname configuration. To diagnose, paste the receiver's IP address/hostname into the
Ping Web page (Diagnostics > Ping/Ping6).
Flow Samples: The total number of flow samples sent to the sFlow receiver.
Counter Samples: The total number of counter samples sent to the sFlow receiver.