Secondary Port ID: The index of the layer 2 interface which is used as ring port 2.
VLAN ID: The VLAN ID assigned to the MRP protocol. The allowed range is 0 - 4094.
Manager Priority: This parameter contains the value for the Manager priority.
Check Media Redundancy: Selects whether monitoring of MRM state is enabled or disabled. Only MRM.
Topology Change Interval, ms: This parameter contains the value of the interval for sending
MRP_TopologyChange frames. The allowed range is 1 - 20. Only MRM.
Topology Change Repeat Count: This parameter contains the value of the interval count which controls
repeated transmissions of MRP_TopologyChange frames. The allowed range is 1 - 5. Only MRM.
Default Test Interval, ms: This parameter contains the value of the default interval for sending MRP_Test frames
on ring ports. The allowed range is 1 - 50. Only MRM.
Short Test Interval, ms: This parameter contains the value of the short interval for sending MRP_Test frames on
ring ports after link changes in the ring. The allowed range is 1 - 30. Only MRM.
Test Monitoring Count: This parameter contains the value of the interval count for monitoring the reception of
MRP_Test frames. The allowed range is 1 - 15. Only MRM.
Test Monitoring Extended Count: This optional parameter contains the value of the extended interval count for
monitoring the reception of MRP_Test frames. The allowed range is 1 - 30. Only MRM.
Non-Blocking MRC Supported: This parameter specifies the ability of the MRM to support MRCs without
BLOCKED port state support in the ring. Only MRM.
React On Link Change: This optional parameter specifies whether the MRM reacts on MRP_LinkChange frames
or not. Only MRM.
Link Down Interval, ms: This parameter contains the value of the interval for sending MRP_LinkDown frames on
ring ports. The allowed range is 1 - 50. Only MRC.
Link Up Interval, ms: This parameter contains the value of the interval for sending MRP_LinkUp frames on ring
ports. The allowed range is 1 to 50. Only MRC.
Link Change Count: This parameter contains the value of the MRP_LinkChange frame count which controls
repeated transmissions of MRP_LinkUp or MRP_LinkDown frames. The allowed range is 1 - 10. Only MRC.
BLOCKED State Supported: This parameter specifies whether the MRC supports BLOCKED state at its ring
ports or not. Only MRC.
Buttons
Apply: Click to save changes.
Reset: Click to undo any changes made locally and revert to previously saved values.
Messages:
The maximum number of entries is 2