Frame Length Check: Configures if frames with incorrect frame length in the EtherType/Length field will be
dropped. An Ethernet frame contains a field EtherType which can be used to indicate the frame payload size (in
bytes) for values of 1535 and below. If the EtherType/Length field is above 1535, it indicates that the field is used
as an EtherType (indicating which protocol is encapsulated in the payload of the frame). If "Frame Length Check"
is enabled, frames with payload size less than 1536 bytes are dropped, if the EtherType/Length field doesn't
match the actual payload length. If "frame length check" is disabled, frames are not dropped due to frame length
mismatch. Note: No drop counters count frames dropped due to frame length mismatch
Buttons
Apply: Click to save changes.
Reset: Click to undo any changes made locally and revert to previously saved values.
Refresh: Click to refresh the page. Any changes made locally will be undone.
Messages: Both PFC and Flow Control cannot both be enabled for the same port