214603 88 Revision A
Display (A) Flashing Alarm Tone Description
ENGINE OIL PRESSURE
X
Continuous loud tone until oil
pressure is regained
Low engine oil pressure
ENGINE TEMPERATURE
X
Ongoing intermittent moderate
tone until temperature is below
102°C (215°F)
Engine temperature over 104°C
(220°F)
HEADER DISENGAGED
None Normal
DISENGAGE HEADER
X None
Header switch is in the ON
position when ignition switch is
turned ON
HEADER OIL PRESS
X
Continuous loud tone until oil
pressure is regained
Low header charge oil pressure
causes header to shut down:
header ON switch must be moved
to OFF position and then to ON
position to restart the header
HYDRAULIC FILTER
X
Single loud tone for 10 seconds,
Repeats every 15 minutes until
condition is corrected
Excessive pressure increase
across hydraulic oil filter
### °C or F HYD
OIL COLD
X
Tone sounds with each flash for
5 seconds and then stops for
1 minute, flashing continues if
oil still cold after 1 minute, tone
sounds again
Hydraulic oil temp <10°C (50°F)
### °C or F HYD OIL HOT
X
Tone with each flash for
5 seconds at 104°C (220°F)
then tone stops for 1 minute
while flashing continues. If oil
still hot after 1 minute, tone
sounds again.
Flashing and steady tone at
temperatures of 110°C (230°F)
and higher
Hydraulic oil temp >104°C (220°F)
but <110°C (230°F)
IN PARK X
One short beep
GSL in N-DETENT, steering
wheel centered, and brakes are
engaged
KNIFE SPEED
OVERLOAD
X
Short beep with each flash until
condition is corrected
Machine overload: knife or disc
speed drops below
programmed value
LOCK SEAT BASE
None
Seat base not detected in cab or
engine-forward position
LOW HYDRAULIC OIL
X
Continuous loud tone for
5 seconds. If condition is not
rectified, single loud tone every
5 minutes
Low hydraulic oil level, header
shuts down automatically if
engaged: Header ON switch must
be moved to OFF position and
then to ON position to restart the
header
OPERATORS STATION