214603 313 Revision A
Figure 5.45: Battery Terminal Location
IMPORTANT:
Batteries are negative grounded. Always connect
starter cable to the positive (+) terminal of battery and
battery ground cable to negative (–) terminal of battery.
Reversed polarity in battery or alternator may result in
permanent damage to electrical system.
10. Attach negative (black) cables (B) to negative posts on
batteries, and tighten clamps. Then attach positive (red)
cables (A) to positive post on batteries and tighten
clamps.
11. Position plastic covers onto clamps.
12. Close the hood. Refer to 5.2.2 Closing Hood (Lower
Position), page 285.
13. Close the platform. Refer to 5.3.2 Closing Platforms
(Standard Position), page 289.
5.8.3 Engine Oil
Checking Engine Oil Level
Check engine oil level daily (every 10 hours) and watch for any signs of leakage.
CAUTION
To avoid bodily injury or death from unexpected startup of machine, always stop engine and remove key
from ignition before leaving operator’s seat for any reason.
NOTE:
During the break-in period, a higher than usual oil consumption should be considered normal.
1. Open the hood to the lowest position. Refer to 5.2.1 Opening Hood (Lower Position), page 284.
2. Operate the engine at low idle and check for leaks at the filter and drain plug.
3. Stop the engine and remove the key. Wait about 5 minutes.