214603 473 Revision A
Cummins
Fault
Code
J1939
SPN
J1939
FMI
Lamp
J1939 SPN
Description
Cummins Description
64
2557 697 3 Amber
Auxiliary PWM
driver #1
Auxiliary PWM driver #1 voltage above
normal, or shorted to high source
2558 697
4 Amber
Auxiliary PWM
driver #1
Auxiliary PWM driver #1 voltage below
normal, or shorted to low source
527 702 3 Amber
Circuit voltage Auxiliary input/output 2 circuit voltage
above normal, or shorted to high source
529 703 3
Amber
Circuit voltage Auxiliary input/output 3 circuit voltage
above normal, or shorted to high source
779 703 11 Amber Auxiliary equipment
sensor input
Warning auxiliary equipment sensor input
#3 (OEM switch) root cause not known
2195 703 14 Red Auxiliary equipment
sensor
Auxiliary equipment sensor input 3 engine
protection critical special instructions
778 723 2 Amber
Engine speed
sensor #2
Engine speed sensor (camshaft) error
data erratic, intermittent, or incorrect
2322 723 2
None
Engine speed
sensor #2
Engine speed/position sensor #2 data
erratic, intermittent, or incorrect
731 723
7
Amber
Engine speed
sensor #2
Engine speed/position #2 mechanical
misalignment between camshaft and
crankshaft sensors mechanical system
not responding properly or out of
adjustment
2555 729 3 Amber Inlet air heater driver
#1
Intake air heater #1 circuit voltage above
normal, or shorted to high source
2556 729
4 Amber Inlet air heater driver
#1
Intake air heater #1 circuit voltage below
normal, or shorted to low source
2426 730 3
None
Intake air heater #2
Intake air heater 2 circuit voltage above
normal, or shorted to high source
2425 730
4 None
Intake air heater #2
Intake air heater 2 circuit voltage below
normal, or shorted to low source
133 974 3 Red Remote accelerator Remote accelerator pedal or lever position
sensor circuit voltage above normal, or
shorted to high source
134 974
4 Red Remote accelerator Remote accelerator pedal or lever position
sensor circuit voltage below normal, or
shorted to low source
288 974 19
Red Remote accelerator
SAE J1939 multiplexing remote accelerator
pedal or lever data error received network
data in error
REFERENCE