EasyManua.ls Logo

NEC UX5000 - Page 258

NEC UX5000
588 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Networking (AMIS)
240 Chapter 2: Features UX Mail Manual
Step 3 Enter the access digits for network callouts.
3.1 FOR LOCAL NETWORK CALLOUTS, SEE CUSTOMIZE: TENANT OPTIONS: [ACCESS DIGITS] NETWORK LOCAL
CALLOUT (PAGE 481).
3.2 FOR LONG DISTANCE NETWORK CALLOUTS, SEE CUSTOMIZE: TENANT OPTIONS: [ACCESS DIGITS] BEFORE NET-
WORK LONG DISTANCE CALLOUT (PAGE 482).
- A typical entry for either option is 9P, where:
9 is the trunk access code.
P is a pause.
- If long distance calls require a leading 1, add it to the access digits (e.g.,
9P1).
By default, there are no entries for these options.
Step 4 To use a Network Remote Mailbox for recording and sending network messages:
4.1 WHEN RECORDING AND SENDING A NETWORK MESSAGE, THE EXTENSION USER MUST DIAL THE NETWORK MAIL-
BOX NUMBER PLUS THE MAILBOX NUMBER IN THE REMOTE SYSTEM.
- If networking with multiple remote systems, you could set up a Network Remote Mailbox
for each system.
4.2 CUSTOMIZE: MAILBOX OPTIONS EDIT: [GENERAL] MAILBOX TYPE (PAGE 405).
- Select Network to enable a Network Mailbox.
By default, there are no Network Mailboxes programmed.
4.3 CUSTOMIZE: MAILBOX OPTIONS EDIT: [NETWORK] TYPE (PAGE 412).
- Select Remote to set up the mailbox as a Network Remote Mailbox.
By default, this option is
Alias (Network Alias Mailbox).
Step 5 To use a Network Alias Mailbox for recording and sending network messages:
5.1 WHEN RECORDING AND SENDING A NETWORK MESSAGE, THE EXTENSION USER JUST DIALS THE NETWORK MAIL-
BOX NUMBER TO LEAVE A MESSAGE AT A SPECIFIC MAILBOX IN THE REMOTE SYSTEM. THEY DONT HAVE TO
ADDITIONALLY ENTER A REMOTE SYSTEM MAILBOX NUMBER.
5.2 CUSTOMIZE: MAILBOX OPTIONS EDIT: [GENERAL] MAILBOX TYPE (PAGE 405).
- Select Network to enable a Network Mailbox.
By default, there are no Network Mailboxes programmed.
5.3 CUSTOMIZE: MAILBOX OPTIONS EDIT: [NETWORK] TYPE (PAGE 412).
- Select Alias to set up the mailbox as a Network Alias Mailbox.
By default, this option is
Alias (Network Alias Mailbox).
5.4 CUSTOMIZE: MAILBOX OPTIONS EDIT: [NETWORK] NETWORK MAILBOX (PAGE 412).
- Enter the number of the mailbox in the remote system the should receive the message when
a user records and sends a message for this network mailbox.
- For example, if the Network Alias Mailbox should automatically leave a message in
remote system mailbox 310, enter 310.
By default, there is no entry for this option.
Step 6 Enter the number of the Automated Attendant in the remote system.
6.1 CUSTOMIZE: MAILBOX OPTIONS EDIT: [NETWORK] NETWORK CALL TYPE (PAGE 413).
-
This is the call type used by the Network Mailbox when delivering messages to the
remote system.
- If it is a long distance call to remote system, select Long Dis.
- When the system delivers a network message, the long distance number is preceded
by the entry you made in Customize: Tenant Options:
[ACCESS DIGITS] BEFORE NET-
WORK LONG DISTANCE CALLOUT (PAGE 482).
- If it is a local number to the remote system
, select Local.
- When the system delivers a network message, the local number is preceded by the
entry you made in Customize: Tenant Options:
[ACCESS DIGITS] NETWORK LOCAL CALL-
OUT (PAGE 481).
- If you don’t want the remote callout number preceded by access digits
, select Internal.

Table of Contents

Other manuals for NEC UX5000

Related product manuals