Command Reference
R&S
®
ZNB/ZNBT
1278User Manual 1173.9163.02 ─ 55
*RST: RRAFter
Example: See SOURce<Ch>:POWer<PhyPt>:CORRection[:ACQuire]
Manual operation: See "Flatness Cal – Pwr Cal Method" on page 489
SOURce<Ch>:POWer<PhyPt>:CORRection:COLLect:RRECeiver <arg0>
Enables or disables calibration of the reference receiver together with the source
power calibration.
Note: It is not possible to disable flatness calibration
(SOURce<Ch>:POWer<PhyPt>:CORRection:COLLect:FLATness) and the refer-
ence receiver calibration simultaneously.
Suffix:
<Ch>
.
Calibrated channel number. This parameter is ignored; the verifi-
cation is either enabled or disabled for all channels.
<PhyPt> Calibrated port number. This parameter is ignored; the verifica-
tion is either enabled or disabled for all sources.
Parameters:
<arg0> Enables (ON) or disables (OFF) reference receiver calibration.
*RST: ON
Example: See SOURce<Ch>:POWer<PhyPt>:CORRection:COLLect:
FLATness on page 1276.
SOURce<Ch>:POWer<PhyPt>:CORRection:DATA:PARameter<Wv>:COUNt?
Gets the number of available power calibrations (both source power and measurement
receiver).
Use SOURce<Ch>:POWer:CORRection:DATA:PARameter<Wv>? to retrieve the
related settings.
Suffix:
<Ch>
.
Number of the calibrated channel.
<PhyPt> This suffix is ignored.
<Wv> This suffix is ignored.
Usage: Query only
Manual operation: See "Port Overview" on page 444