CALCulate:FMODel:ISD<Ph_pt>:RUN[:STATe] <Boolean>
For a fixture modeling with the ISD tool, this command allows to specify the ports to
which the deembedding files shall be assigned after the tool has run.
Suffix:
<Ph_pt>
.
Physical port number for single-ended deembedding, logical port
number for balanced deembedding.
Parameters:
<Boolean> 1 (ON) if a deembedding file shall be assinged to port <Pt>, 0
(OFF) otherwise
Example: See Chapter 9.2.8, "Fixture Modeling", on page 1415
Manual operation: See "Apply" on page 595
CALCulate:FMODel:ISD<Ph_pt>:SCALe:ATTenuation
<AttenLeadInScaling>
Scales the test coupon’s attenuation (dB).
Sets/gets the atten_scale 1 batch mode parameter of the ISD tool
Suffix:
<Ph_pt>
.
This suffix is ignored.
Parameters:
<AttenLeadInScaling>
Manual operation: See "Scaling for Lead In Atten" on page 597
CALCulate:FMODel:ISD<Ph_pt>:SCALe:FREQuency <MaxFrequency>
Defines the maximum frequency to deembed.
Corresponds to the max_frequency batch mode parameter of the ISD tool.
Suffix:
<Ph_pt>
.
This suffix is ignored.
Parameters:
<MaxFrequency> Default unit: Hz
Manual operation: See "Max Freq to Deembed" on page 599
CALCulate:FMODel:ISD<Ph_pt>:SCALe:FTIMe <FltLeadInScalingTime>
Overrides the lead-in’s flight time in case the through-trace test coupon is a bit too
short or too long.
Sets/gets the atten_scale 1 batch mode parameter of the ISD tool.