Main Service Program Mode Tables
SM 5-11 B234/B235/B236/D101/D102/D103
Service
Tables
014 Fusing Lamp Switching After Low Power Mode
Specifies the temperature at which 1 of the 3 fusing lamps is switched off before
reaching the target standby temperature when the machine returns from the low
power mode. The 3rd lamp is switched off before reaching the target standby
temperature to prevent overshooting the target temperature.
SP1105-1 – SP1104 14 = Actual Temperature
[-20 ~ 0/ */1 deg C]
* B234/D101: -10
* B235/D102: -10
* B236/D103: -20
015 1st Print After Low Power Mode
Sets the temperature at which the first sheet is allowed to print before the hot roller
reaches the target standby temperature after returning from low power mode.
[-50 ~ 0/ */ 1 deg C]
* B234/D101: -20
* B235/D102: -20
* B236/D103: -5
016 Fusing Temp Switch
This SP can be adjusted for the paper type, efficiency of fusing, and to reduce paper
curl.
0: Medium
1: Low
2: High
Raise the temperature setting if you see loose toner, indicating that the toner has
not fused completely with the surface of the paper.
Lower the temperature setting if the paper is excessively curled after it leaves the
machine.
Note: This SP is equivalent to Super User SP Mode SP1740 001.
[0~2/0/1]
017 Small Size (2 Copies)
This SP adjusts the fusing temperature for "#2 Copies". These are small paper sizes
(B5 SEF and smaller). The value entered here is added to the "Ready" temperature
(standby temperature). The job will begin when the hot roller reaches: Standby Temp.
+ SP1105 17 setting.
[0~20/10/1 degrees]
018 Small Size (Switch to 1 Lamp)
This SP selects one fusing lamp for small paper sizes (B5 SEF and smaller).
[0~2/1/1]
019 Small Size (Switch to 2 Lamps)
This SP selects two fusing lamps for small paper sizes (B5 SEF and smaller).
[0~2/1/1]
1106 Fusing Temperature Display
Displays the fusing temperature.
1107 Fusing Idling Time Setting
001 Normal/High Temp Mode
002 Low Temp Mode
Sets the length of time the hot roller is allowed to rotate
before the first sheet is fed. This idling time allows the
hot roller to heat up faster.
[0~60 / 10 / 1 s]