MAIN SERVICE PROGRAM MODE TABLES
B234/B235/B236/D101/D102/D103 5-26 SM
005 Front – On/Off Setting: Low Speed Mode
Switches the PTL on and off for the front side of the paper passing through the
fusing unit in the low speed mode.
Note: When feeding thick paper or OHP transparencies, this setting is always off.
[0~1/0/1]
0: Off
1: On
006 Front – Off Timing Adj.: Low Speed Mode
This SP adjusts the length of the space from the leading edge where the PTL
quenching is applied to the front side in low speed mode. For example, if you set
+5, 5 mm from the leading edge will be quenched.
[-5~10/2/0.1 mm]
007 Back– On/Off Setting: Low Speed Mode
Switches the PTL on and off for the rear side of the paper passing through the
fusing unit in the duplex mode in low speed mode.
[0~1/0/1]
0: Off
1: On
Note:
• When this setting is switched on, make sure that the setting of SP2940 016 is
the same as the default setting of SP2940 009.
When feeding thick paper or OHP transparencies, this setting is always off.
008 Back – Off Timing Adj.: Low Speed Mode
This SP adjusts the length of the space from the leading edge where the PTL
quenching is applied to the rear side in slow speed mode. For example, if you set
+5, 5 mm from the leading edge will be quenched.
[-5~10/2/0.1 mm]
2801 TD Sensor Initial Setting
Performs the TD sensor initial setting. This SP mode controls the voltage applied to the
TD sensor to make the TD sensor output about 2.5 V. After finishing this, the TD sensor
output voltage is displayed. Press Start to execute.
You must enter the developer lot number. (The lot number is stenciled on the top edge
of the developer package.)
Use this mode only after changing the TD sensor or the developer.
2803 Charge Corona Cleaner On
Turns on the corona wire cleaner manually. Press Start to execute.
When copy density across the paper is uneven, clean the wire with this SP.
2804 Charge Corona Cleaner Setting
001 Corona Wire Cleaner Operation Setting
Selects when automatic corona wire cleaning is done.
[0~2 / 2 / 1]
0: OFF
1: At the beginning process control and at intervals selected with SP2804 002
2: At intervals selected with SP2804 002 only (not at the beginning of process control).
002 Corona Wire Cleaner Interval
Selects the interval for automatic corona wire cleaning.
[100~10000 / 5000 / 100 copies]