Main Service Program Mode Tables
SM 5-25 B234/B235/B236/D101/D102/D103
Service
Tables
2507 Pattern During Jobs
001 Set Operation This On/Off setting determines whether the toner entry patterns
are created on the drum during and at the end of jobs.
Default: OFF (no patterns)
002 Set Interval This SP sets the count for the number of sheets to print before
the patterns are created on the drum. When the count exceeds
this setting, the machine retracts the transfer belt from the drum,
creates the patterns, resets the transfer belt against the drum
and continues the job.
[1~2000/50/ 1 K sheets]
003 Set Number of
Patterns
This setting determines the number of patterns to be created on
the drum.
[1~200/10/1]
SP2602 PTL Settings
Use this SP to adjust the on/off timing of the PTL (pre-transfer lamp).
Note:
• This PTL light emitted from the PTL is intended to reduce charge on the drum
and improve image transfer from drum to paper.
• However, adjusting the on/off of the PTL can caused blurred images appear at
the leading edges of the paper. Therefore, the default setting for SP2602 001
is set to "Off".
001 Front – On/Off Setting
Switches the PTL on and off for the front side of the paper passing through the
fusing unit at normal speed.
Note: When feeding thick paper or OHP transparencies, this setting is always off.
[0~1/0/1]
0: Off
1: On
PTL timing can be adjusted with SP2602 002.
002 Front – Off Timing Adj.
This SP adjusts the length of the space from the leading edge where the PTL
quenching is applied to the front side at normal speed. For example, if you set
+5, 5 mm from the leading edge will be quenched.
[-5~10/2/0.1 mm]
003 Back – On/Off Setting
Switches the PTL on and off for the rear side of the paper passing through the
fusing unit in the duplex mode at normal speed.
[0~1/0/1]
0: Off
1: On
Note:
• When this setting is switched on, make sure that the setting of SP2940 008 is
the same as the default setting of SP2940 001.
• When feeding thick paper or OHP transparencies, this setting is always off.
004 Back – On/Off Timing Adj.
This SP adjusts the length of the space from the leading edge where the PTL
quenching is applied to the rear side at normal speed. For example, if you set +5,
5 mm from the leading edge will be quenched.
[-5~10/2/0.1 mm]