Main Service Program Mode Tables
SM 5-53 B234/B235/B236/D101/D102/D103
Service
Tables
5120 Mode Clear Opt. Counter Removal
Do not change. Japan Only
[0~2/1]
0: Yes. Normal reset
1: Standby. Resets before job start/after completion
2: No. Normally no reset
5121 Counter Up Timing
Determines whether the optional key counter counts up at paper feed-in or at
paper exit.
[0~1/1]
0: Feed count
1: No feed count
5126 Original Size: Set F-Size
There are presently three F-type sizes (8½ x 13, 8 ¼ x 13, 8 x 13) and the APS
sensors are not sensitive enough to distinguish between these types. Use this SP
to select the F-type size that the customer uses most frequently so the ASP
sensors can detect an F-type size accurately.
[0~2/0/1]
0: 8 ½ x 13
1: 8 ¼ x 13
2: 8 x 13
5127 APS OFF Mode
This SP can be used to switch APS (Auto Paper Select) off when a coin lock or
pre-paid key card device is connected to the machine.
[0~1/1]
0: On
1: Off
5131 Paper Size Type Selection
Selects the paper size type (for originals and copy paper). (The default setting depends
on the setting of DIP SW 1 and 2 on BCU.)
[JP]: Japan
[NA]: North America
[EU]: Europe
[CH]. China
After changing the value, turn the main power switch off and on.