Main Service Program Mode Tables
SM 5-67 B234/B235/B236/D101/D102/D103
Service
Tables
153 Selection Dial/Push
This SP displays the classification (tone or pulse) of the telephone line to the
access point for Cumin-M. The numbered displayed (0 or 1) is the result of the
execution of SP5816 151. However, this setting can also be changed manually.
[0~1/0/1]
0: Tone Dialing Phone
1: Pulse Dialing Phone
Inside Japan "2" may also be displayed:
0: Tone Dialing Phone
1: Pulse Dialing Phone 10PPS
2: Pulse Dialing Phone 20PPS
154 Outside Line/Outgoing Number
The SP sets the number that switches to PSTN for the outside connection for
Cumin-M in a system that employs a PBX (internal line).
If the execution of SP5816 151 has succeeded and Cumin-M has connected
to the external
line, this SP display is completely blank.
If Cumin-M has connected to an internal
line, then the number of the
connection to the external line is displayed.
If Cumin-M has connected to an external line, a comma is displayed with the
number. The comma is inserted for a 2 sec. pause.
The number setting for the external line can be entered manually (including
commas).
155 Remove Service: PPP Recognition Timeout
Sets the length of the timeout for the Cumin-M connection to its access point.
The timeout is the time from when the modem sends the ATD to when it
receives the result code.
[1~65536/60/1]
156 Dial Up User Name
Use this SP to set a user name for access to remote dial up. Follow these rules
when setting a user name:
Name length: Up to 32 characters
Spaces and # allowed but the entire entry must be enclosed by double
quotation marks (").
157 Dial Up Password
Use this SP to set a password for access to remote dial up. Follow these rules
when setting a user name:
Name length: Up to 32 characters
Spaces and # allowed but the entire entry must be enclosed by double
quotation marks (").
159 Remote Service: Carrier Send Level
This SP sets the level of the carrier signal for Cumin-M data transmissions.
[0~15/3/1]
160 Remote Service: AT command
This SP allows you to add an AT command to the initialization of the Cumin-M
modem. This SP sets the AT command for both initialization and wait time of
and outgoing call. It also includes the NULL instruction.
Default: 0, up to 8 characters allowed.
161 Local Phone Number
Use this SP to set the telephone number of the line where Cumin-M is
connected. This number is transmitted to and used by the Call Center to return
calls.
Limit: 24 numbers (numbers only)