Parameters
Overview of parameters
1-14
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Scaling
Specification of the reference variable with which a signal value is automatically
converted for a BICO interconnection.
The following reference variables are available:
p2000 ... p2006: Reference speed, reference voltage, etc.
PERCENT: 1.0 = 100 %
4000H: 4000 hex = 100 %
Dyn. index (dynamic index)
For parameters with a dynamic index [0...n], the following information is specified
here:
Data set (if available).
Parameter for the number of indices (n = number - 1).
The following information can be contained in this field:
"CDS, p0170" (Command Data Set, CDS count)
Example:
p1070[0] main setpoint [command data set 0]
p1070[1] main setpoint [command data set 1], etc.
"DDS, p0180" (Drive Data Set, DDS count)
"EDS, p0140" (Encoder Data Set, EDS count)
"MDS, p0130" (Motor Data Set, MDS count)
"PDS, p0120" (Power unit Data Set, PDS count)
Data sets can only be created and deleted when p0010 = 15.
U Operation U: Run
Pulses are enabled.
T Ready T: Ready to run
The pulses are not enabled and the status "C(x)" is not active.
Note:
Information on the data sets can be taken from the following references:
Operating Instructions SINAMICS G120D Frequency Converter with
CU240D-2 Control Units.
Operating Instructions SINAMICS G120D Frequency Converter with
CU250D-2 Control Units.