p1514[0...n] Supplementary torque 2 scaling / M_suppl 2 scal
p1517[0...n] Accelerating torque smoothing time constant / M_accel T_smooth
p1520[0...n] CO: Torque limit upper / M_max upper
p1521[0...n] CO: Torque limit lower / M_max lower
p1524[0...n] CO: Torque limit upper/motoring scaling / M_max up/mot scal
p1525[0...n] CO: Torque limit lower scaling / M_max lower scal
p1530[0...n] Power limit motoring / P_max mot
p1531[0...n] Power limit regenerative / P_max gen
p1553[0...n] Stall limit scaling / Stall limit scal
p1570[0...n] CO: Flux setpoint / Flex setp
p1573[0...n] Flux threshold value magnetizing / Flux thresh magnet
p1574[0...n] Voltage reserve dynamic / U_reserve dyn
p1580[0...n] Efficiency optimization / Efficiency opt.
p1582[0...n] Flux setpoint smoothing time / Flux setp T_smth
p1584[0...n] Field weakening operation flux setpoint smoothing time / Field weak T_smth
p1594[0...n] Field-weakening controller P gain / Field_ctrl Kp
p1596[0...n] Field weakening controller integral-action time / Field_ctrl Tn
p1610[0...n] Torque setpoint static (SLVC) / M_set static
p1611[0...n] Supplementary accelerating torque (SLVC) / M_suppl_accel
p1616[0...n] Current setpoint smoothing time / I_set T_smooth
p1654[0...n] Curr. setpoint torque-gen. smoothing time field weakening range / Isq_s T_smth FW
p1702[0...n] Isd current controller pre-control scaling / Isd_ctr_prectrScal
p1703[0...n] Isq current controller pre-control scaling / Isq_ctr_prectrScal
p1715[0...n] Current controller P gain / I_ctrl Kp
p1717[0...n] Current controller integral-action time / I_ctrl Tn
p1726[0...n] Quadrature arm decoupling scaling / Transv_decpl scal
p1727[0...n] Quadrature arm decoupling at voltage limit scaling / TrnsvDecplVmaxScal
p1730[0...n] Isd controller integral component shutdown threshold / Isd_ctr I_compDeac
p1731[0...n] Isd controller combination current time component / Isd ctrl iCombi T1
p1740[0...n] Gain resonance damping for encoderless closed-loop control / Gain res_damp
p1744[0...n] Motor model speed threshold stall detection / MotMod n_thr stall
p1745[0...n] Motor model error threshold stall detection / MotMod ThreshStall
p1749[0...n] Motor model increase changeover speed encoderless operation / Incr n_chng no enc
p1750[0...n] Motor model configuration / MotMod config
p1752[0...n] Motor model changeover speed operation with encoder / MotMod n_chgov enc
p1753[0...n] Motor model changeover speed hysteresis operation with encoder / MotMod n_chgovHysE
p1755[0...n] Motor model changeover speed encoderless operation / MotMod n_chgSnsorl
p1758[0...n] Motor model changeover delay time closed/open-loop control / MotMod t cl_op
p1759[0...n] Motor model changeover delay time open/closed-loop control / MotMod t op_cl
p1760[0...n] Motor model with encoder speed adaptation Kp / MotMod wE n_ada Kp
p1761[0...n] Motor model with encoder speed adaptation Tn / MotMod wE n_ada Tn
p1764[0...n] Motor model without encoder speed adaptation Kp / MotMod woE n_adaKp
p1767[0...n] Motor model without encoder speed adaptation Tn / MotMod woE n_adaTn
p1774[0...n] Motor model offset voltage compensation alpha / MotMod offs comp A
p1775[0...n] Motor model offset voltage compensation beta / MotMod offs comp B
p1780[0...n] Motor model adaptation configuration / MotMod adapt conf
p1784[0...n] Motor model feedback scaling / MotMod fdbk scal
p1785[0...n] Motor model Lh adaptation Kp / MotMod Lh Kp
p1786[0...n] Motor model Lh adaptation integral time / MotMod Lh Tn
r1787[0...n] Motor model Lh adaptation corrective value / MotMod Lh corr
p1795[0...n] Motor model kT adaptation integral time / MotMod kT Tn
r1797[0...n] Motor model kT adaptation corrective value / MotMod kT corr
p1800[0...n] Pulse frequency setpoint / Pulse freq setp