Chapter 5
Maintenance and Repair
P/N 57150002, Revision 5.0 5 - 149 Trimble S, VX, SPS & RTS Service Manual
F
IPC board PASS, firmware update,
Hardware Angle, MSB board
replacement, Initialize
instrument data
KNB board PASS, Knob calibration
Optical plummet Alignment
PSM board PASS, all function tests (not
centre unit), firmware update
Radio / battery side cover PASS, Internal battery, Radio
range test (robotic)
Radio module PASS, configuration, range
test
Servo side cover PASS, Knob calibration
TCU attachment PASS, TCU connection
Tilt sensor PASS, Tilt offset, firmware
update
Vertical angle disc PASS, Servo & Angle
calibration, cleanliness test
Vertical SRC board incl. magnets PASS, Servo & Angle
calibration, cleanliness test
Vertical MSB board incl. motor
winding
Centring of MSB board. PASS, Hardware Angle, MSB
board replacement, Servo &
Angle calibration, cleanliness
test
DR300+ / DR PLUS Distance unit
Greywedge assembly PASS, All steps in EDM
PRB board Fibre adjustments / Reference
signal
PASS, All steps in EDM
Reference greywedge Fibre adjustments / Reference
signal
PASS, All steps in EDM
TPB board Fibre adjustments / Reference
signal
PASS, All steps in EDM,
firmware update
Laser pointer / tracker transmitter Laser pointer PASS, Laser pointer
High Precision / DR Standard / DR
Distance unit
Transmitter unit Fibre adjustments / Reference
signal
PASS, All steps in EDM
Board / module replaced Adjustment Check / test