Chapter 6
Adjustment and verification
Trimble S, VX, SPS & RTS Service Manual6 - 126 P/N 57150002, Revision 5.0
F
Tracker unit
• Determination of reticle collimation “c” and “i”
• Determination tracker receiver collimation “ct” and “it”
• Tracker receiver alignment (within screw holes only)
• Verification of tracker receiver alignment (“ct” and “it” collimation)
• Check of tracker crosstalk
• Tracker transmitter alignment
• Laser power test
• Tracker collimation
Precondition: the angle system is working well, see “Angle unit” on page 6-28. and the reticle are
well adjusted, see “Reticle” on page 6-33..
Tools and equipment
Description Part number
Tracker transmitter adj. tool 79351001
Tracker illumination tool 79445001
Light trap (tracker crosstalk) 79700001
Cable pointer illumination 79772001
Torque wrench 120 Ncm T71600280
2 x Torx T8 bits Local tool
Hexagon screw driver 1.3mm Local tool
Hexagon screw driver 2mm Local tool
Hexagon screw driver 2,5mm (ball tipped) Local tool
Power supply (5 Volt) Local tool