Chapter 6
Adjustment and verification
P/N 57150002, Revision 5.0 6 - 27 Trimble S, VX, SPS & RTS Service Manual
F
5 Optional - Test
Vertical oscillation
compensation.
A. Select Test
compensation
check
box.
B. Aim to a prism target
and click
Measure.
C. Observe if the cross-
hairs are stable, click
Yes or No.
D. Click
Face 2 to move
instrument in second
face.
E. Observe if the cross-
hairs are stable, click
Yes or No.
If instrument
oscillates with
active
compensation,
check
compensation
value and
regrease
bearings. If still
fails check size
of tracker
transmitter
beam.
The status of
compensation is
displayed ON/OFF.
Item Performance Description Result Notes