Chapter 6
Adjustment and verification
Trimble S, VX, SPS & RTS Service Manual6 - 86 P/N 57150002, Revision 5.0
F
Fig. 6-95 Message box Release Measurement)
Fig. 6-96 Possible messages after measurement is done
8 Check measurements. The yellow highlighted
lines in the list, see Fig. 6-
92 on page 6-83 are
representing baselines for
check measurements.
After the last
measurement the
offset values are
displayed.
Item Performance Description Result Notes
effects that all following
measurements will be cancelled,
the offset determination is terminated
allows to skip a baseline in the
list and continue to the next
positions the instrument to
the next target, ONLY if the angles to the
click this button on the
first target and when clicking Position
the software will automatically position
the instrument to the next target
the distance
to the DR target or prism
a help to position
the instrument
targets are set in the baseline editor
Cancel
Skip
Position
Position offset
Measure
Laser pointer
If the measured distance is within tolerances,
the measurement can be completed,
If not, click and the measurement can be
repeated
, the measurement may be repeated.
, the measurement will be marked as failed in the
status column. It will not be included in the offset
calculation when enough bas elines are available
Ye s
No
Ye s
No