EasyManuals Logo

Trimble S User Manual

Default Icon
596 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #454 background imageLoading...
Page #454 background image
Chapter 6
Adjustment and verification
Trimble S, VX, SPS & RTS Service Manual6 - 118 P/N 57150002, Revision 5.0
F
5 Check crosstalk. A. Mount the Light trap
tool on the front lens.
B. Select
Cross talk check
check box.
C. Click
Cross talk
measure
.
D. Click
Stop to finnish
test.
3 Clean the front lens
and make sure the
Light trap tool is
cleaned. Dust and
fingerprints can affect
the result.
If value is still too
high:
Check the transmitter
and receiver
adjustment, see page
6-90.
Check if APD is
tighten with screw,
see Fig. 5-94 on page
5-97 .
Check adjustment of
receiver fibre to APD
signal maximum, see
see page 6-105.
6 Check signal/noise
ratio.
A. Mount the Light Cover
Front lens.
B. Select
Signal noise
check
check box.
C. Click
Signal noise
measurement
.
> 10 If value out of
tolerance, check
receiver APD value
and reference signal.
7 Distance measurement
in DR mode.
A. Aim to the 2,5 meter
DR target.
B. Select
Distance
measurement
check
box.
C. Click
DR measure
button.
D. Click
Stop to finnish
test.
<3mm The red spot of
transmitter should
blinking periodically.
If no measurement is
possible, or the value
is out of tolerance,
check the transmitter/
laser pointer
adjustment, see Fig.
6-107 on page 6-96
and run EDM offset
determination, see
page 6-120.
Item Performance Description Result Notes

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Trimble S and is the answer not in the manual?

Trimble S Specifications

General IconGeneral
BrandTrimble
ModelS
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals