7. System Setup
7.3 Power up and Status check
General
Use the following steps to power up your Event Master s eries processor and check system status.
Prerequisite
Ensure that y our sy stem is properly installed and cabled.
Ensure that you are familiar with the System M enu. For details on all m enus, p lease refer to chapter "Front Panel Menu
orientation", page 63.
Power up system and check system status
1. Turn on the unit and wait while it initializes. During the initialization process the front panel displays: “Program Loading Pleas e
Wait”.
The Status Men u is autom atically displayed after initialization is c ompleted.
2. Power u p all peripherals, such as display devices (projectors, monitors) and sources.
3. Turn on the PC and run the Event Master Toolset Software.
The syste m co n gur ation page is the rst page that appears when the Event Master Toolset Software is launched.
4. On the St atus Me nu:
- S ystem1 is the default v alue d isplayed as S ystem Name if this is the rst start of the unit. This name can be chan
ged in the
conguration page of th e GUI.
- Ensure the Event Master series processor is connected on the local network. If there is no internet connection, or if a DHCP
server has not been found, the IP address is 000.000.000.000. In this case, re-check all Ethernet con nections. After checking
connections, if devices still report “Not Connected,” use the procedure "Communication setup", page 224.
222
R5905948 EVENT MASTER DEVICES 17/07/2017

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Barco S3 and is the answer not in the manual?

Barco S3 Specifications

General IconGeneral
BrandBarco
ModelS3
CategoryComputer Hardware
LanguageEnglish

Related product manuals