7 Save/Recall/Print
7.2 Recall
Status Bits/OPC
dependencies
Sequential - aborts the current measurement
Backwards
Compatibility SCPI
:MMEMory:LOAD:CONStln:STATe <filename>
7.2.34 Sync Pattern
Selects a file from which to import the sync pattern data.
Sync Pattern files are CSV files, and contain the sync pattern data in a form that can
be imported into Excel or similar spreadsheets, as well as header data that gives
information on the patterns.
Sync Pattern files have the extension .csv.
A set of preloaded Sync Pattern files can be found in the directory:
My Documents\VMA\DDEMOD\SyncPattern
This is also the default filepath.
Remote Command
:MMEMory:LOAD:DDEMod:SYNC:PATTern <filename>
Example Import the pattern string from the file mySyncPattern.csv in the current path:
:MMEM:LOAD:DDEM:SYNC:PATT "mySyncPattern.csv"
Dependencies Only appears in VMA Mode, in the Digital Demod measurement
Errors are reported if the file is empty or missing, or if the file type does not match, or if there is a
mismatch between the file type and the destination data type
Annotation After recall is complete, an advisory is displayed in the message bar confirming the sync pattern
strings were loaded
Status Bits/OPC
dependencies
Sequential - aborts the current measurement
Backwards
Compatibility SCPI
:MMEMory:LOAD:SYNC:PATTern <filename>
7.2.35 Filter Coefficients
Selects a file from which to import the meas/ref filter coefficients data.
Filter Coefficients files are CSV files, and contain the filter coefficients data in a form
that can be imported into Excel or similar spreadsheets, as well as header data that
gives information on the filters.
You can specify whether you want the Meas Filter or Reference Filter coefficients by
using the radio button that appears when Filter Coefficients is selected in the Recall
menu.
Filter Coefficients files have the extension .csv, and the default path is:
Vector Modulation Analyzer Mode User's &Programmer's Reference 2339

Table of Contents

Other manuals for Keysight x-series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight x-series and is the answer not in the manual?

Keysight x-series Specifications

General IconGeneral
Analysis BandwidthUp to 1 GHz (depending on model)
Real-Time BandwidthUp to 1 GHz (depending on model)
Form FactorBenchtop
ConnectivityLAN, USB, GPIB
Resolution Bandwidth1 Hz to 10 MHz (depending on model)