7 Save/Recall/Print
7.2 Recall
waveform segment may not keep phase continuity during the ARB memory operation. The waveform is
replayed after the ARB operation is finished
When in Sequence Analyzer Mode, and Include Source is Yes, an attempt to delete a file from ARB
memory is rejected with an error . When Include Source is No, and you specify a file that does not exist
within ARB memory, an error is generated
7.2.26 Delete All From ARB Memory
Removes all segments from ARB memory.
Remote
Command
:SOURce:RADio:ARB:DELete:ALL
Example
:SOUR:RAD:ARB:DELete:ALL
Notes If you attempt to delete all files from ARB memory when there are waveform files used in the Sequencer
function of the List Sequencer and the Sequencer state is ON, all files except the files currently being
used in list sequencer are deleted, and an error is generated
If the ARB is ON and you load a file to ARB memory or delete a file from ARB memory, the playing
waveform segment may not keep phase continuity during the ARB memory operation. The waveform is
replayed after the ARB operation is finished
When in Sequence Analyzer Mode, and Include Source is Yes, an attempt to delete all files from ARB
memory is rejected with an error. When Include Source is No, and you attempt to delete all files from
ARB memory when the ARB is currently playing a file, all files except the one playing are deleted and an
error is generated
7.2.27 Set Default Directory (Remote Command Only)
Sets the default directory for loading ARB files from SCPI.
Remote
Command
:SOURce:RADio:ARB:DEFault:DIRectory <string>
:SOURce:RADio:ARB:DEFault:DIRectory?
Example
:SOUR:RAD:ARB:DEF:DIR "D:\ArbFiles"
:SOUR:RAD:ARB:DEF:DIR?
Notes Sets the default directory to be used as a search location for waveform segments that are required to be
loaded into ARB memory for playback of a waveform sequence, and as a search location for selecting
waveforms using SCPI
State Saved Persistent, survives a power cycle and a preset but not saved in the instrument state
7.2.28 Query ARB Memory File List (Remote Query Only)
Queries the instrument for the list of waveform segments in the ARB memory.
2336 Vector Modulation Analyzer Mode User's &Programmer's Reference

Table of Contents

Other manuals for Keysight x-series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight x-series and is the answer not in the manual?

Keysight x-series Specifications

General IconGeneral
Analysis BandwidthUp to 1 GHz (depending on model)
Real-Time BandwidthUp to 1 GHz (depending on model)
Form FactorBenchtop
ConnectivityLAN, USB, GPIB
Resolution Bandwidth1 Hz to 10 MHz (depending on model)

Related product manuals