3 VMA Mode
3.6 Occupied BW Measurement
Set by :SYST:DEF MISC, but not affected by *RST or :SYSTem:PRESet
State Saved Not saved in instrument state
Backwards
Compatibility
Notes
:SYST:PRES no longer turns on :DISPlay:ENABle as it did in legacy analyzers
3.6.5.3 View
Contains controls for selecting the current View, and for editing User Views.
View
See "Views" on page 935
User View
Lets you choose a View from the saved User Views for the current measurement.
This panel only appears if a User View exists for the current measurement.
Remote
Command
:DISPlay:VIEW:ADVanced:SELect <alphanumeric>
:DISPlay:VIEW:ADVanced:SELect?
Example Select Baseband as the current View
:DISP:VIEW:ADV:SEL “Baseband”
Notes You must be in the measurement whose View you are trying to set to send the command. You can only
set Views for the current measurement using this command
For predefined views, the parameter is derived from the view name that is shown in the View list in the
user interface. For example, if you are trying to select the Trace Zoom view in the Swept SA
measurement, you send:
:DISP:VIEW:ADV:SEL "Trace Zoom"
because “Trace Zoom” is the name of the View as seen in the Mode/Meas dialog or in the Display, View
menu
You cannot use the legacy View parameter (which in this case would be TZOom) with
:DISP:VIEW:ADV:SEL
<alphanumeric> is case insensitive; you can specify mixed case, however the name will be
evaluated on a single case. Thus, both of the following forms work:
:DISP:VIEW:ADV:SEL "Trace Zoom"
:DISP:VIEW:ADV:SEL "TRACE ZOOM"
If the specified view is not a valid View, the query returns the error message “-224, Illegal parameter
value; View with the name <alphanumeric> does not exist”
If the display is disabled (via :DISP:ENAB OFF) then the error message “-221, Settings conflict;
View SCPI cannot be used while Display is disabled” is generated
993 Vector Modulation Analyzer Mode User's &Programmer's Reference

Table of Contents

Other manuals for Keysight x-series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight x-series and is the answer not in the manual?

Keysight x-series Specifications

General IconGeneral
Analysis BandwidthUp to 1 GHz (depending on model)
Real-Time BandwidthUp to 1 GHz (depending on model)
Form FactorBenchtop
ConnectivityLAN, USB, GPIB
Resolution Bandwidth1 Hz to 10 MHz (depending on model)

Related product manuals