Lantronix SISPM1040-xxxx-L3 Web User Guide
33856 Rev. A https://www.lantronix.com/ 301
Another instance use the same Working port: Instance is inactive because another instance uses the
same Working port.
State, Warning: If the operational state is Active, the APS instance is indeed active, but it may be that it doesn't
run as the administrator thinks, because of configuration errors, which are reflected in the warnings below.
The Warning information is indicated by
•: no warning, •: warning. Use the tooltip to get detailed warning
information.
State, Protection: The possible protection group states. The letters refer to the state as described in G.8031
Annex.
No request Working: A.
No request Protecting: B.
Lockout: C.
Forced Switch: D.
Signal fail Working: E.
Signal fail Protecting: F.
Manual switch to Protecting: G.
Manual switch to Working: H.
Wait to restore: I.
Do not revert: J.
Exercise Working: K.
Exercise Protecting: L.
Reverse request Working: M.
Reverse request Protecting: N.
Signal degrade Working: P.
Signal degrade Protecting: Q.
Defect state, Working, Protection: The possible values of this field are shown below:
ok: The port defect state is OK
sd: The port defect state is Signal Degrade
sf: The port defect state is Signal Fail
TxAps, RxAps – Request: The possible transmitted or received APS request according to G.8031, Table 11-1.
nr: No Request.
dnr: Do Not Revert.
rr: Reverse Request.
exer: Exercise.
wtr: Wait-To-Restore.
ms: Manual Switch.
sd: Signal Degrade.
sfW: Signal Fail for Working.
fs: Forced Switch.
sfP: Signal Fail for Protect.
lo: Lockout.
TxAps, ReSignal: Transmitted requested signal according to G.8031 figure 11-2.
TxAps, BrSignal: Transmitted bridged signal according to G.8031 figure 11-2
RxAps, ReSignal: Received requested signal according to G.8031 figure 11-2
RxAps, BrSignal: Received bridged signal according to G.8031 figure 11-2