214603 475 Revision A
Cummins
Fault
Code
J1939
SPN
J1939
FMI
Lamp
J1939 SPN
Description
Cummins Description
66
2374 1209 4 Amber Exhaust gas pressure Exhaust gas pressure sensor circuit
voltage below normal, or shorted to low
source
338 1267 3
Amber Vehicle accessories
relay driver
Idle shutdown vehicle accessories relay
driver circuit voltage above normal, or
shorted to high source
339 1267
4 Amber Vehicle accessories
relay driver
Idle shutdown vehicle accessories relay
driver circuit voltage below normal, or
shorted to low source
272 1347 3 Amber Fuel pump
pressurizing assembly
#1
High fuel pressure solenoid valve circuit
voltage above normal, or shorted to
high source
271 1347 4 Amber Fuel pump
pressurizing assembly
#1
High fuel pressure solenoid valve circuit
voltage below normal, or shorted to
low source
281 1347
7
Amber Fuel pump
pressurizing assembly
#1
High fuel pressure solenoid valve #1
mechanical system not responding properly
or out of adjustment
497 1377 2 Amber
Switch circuit
Multiple unit synchronization switch circuit
data erratic, intermittent, or incorrect
649 1378 31 Amber
Blinking
Engine oil change
interval
Change lubricating oil and filter
condition exists
297 1388 3
Amber Auxiliary pressure
Auxiliary pressure sensor input #2 circuit
voltage above normal, or shorted to high
source
298 1388 4 Amber Auxiliary pressure
Auxiliary pressure sensor input #2 circuit
voltage below normal, or shorted to
low source
296 1388 14
Red Auxiliary pressure
Auxiliary pressure sensor input 1 special
instructions
211 1484 31 None J1939 error Additional auxiliary diagnostic codes logged
condition exists
1256 1563 2
Amber
Control module
identification input
state
Control module identification input state
error data erratic, intermittent, or incorrect
1257 1563 2 Red
Control module
identification input
state
Control module identification input state
error data erratic, intermittent, or incorrect
199 1661
4 Amber
Engine automatic
start lamp
Engine automatic start lamp driver circuit
voltage above normal, or shorted to
high source
REFERENCE
66. The descriptions of Cummins J1939 SPN codes are subject to change at their discretion.