214603 476 Revision A
Cummins
Fault
Code
J1939
SPN
J1939
FMI
Lamp
J1939 SPN
Description
Cummins Description
67
2263 1800 16 Amber Battery temperature Battery temperature data valid but above
normal operational range moderately
severe level
2264 1800 18
Amber Battery temperature Battery temperature data valid but below
normal operational range moderately
severe level
1239 2623 3
Amber Accelerator pedal
position
Accelerator pedal or lever position sensor 2
circuit voltage above normal, or shorted
to high source
1241 2623
4 Amber Accelerator pedal
position
Accelerator pedal or lever position sensor 2
circuit voltage below normal, or shorted to
low source
2346 2789 15 None
System diagnostic
code #1
Turbocharger turbine inlet temperature
(calculated) data valid but above normal
operational range least severe level
2347 2790 15
None
System diagnostic
code #1
Turbocharger compressor outlet
temperature (calculated) data valid but
above normal operational range least
severe level
757
2802 31
Amber Electronic control
module
Electronic control module data lost
condition exists
2115 2981 3 Amber
Coolant pressure Coolant pressure 2 circuit voltage above
normal, or shorted to high source
2116 2981
4 Amber
Coolant pressure Coolant pressure 2 circuit voltage below
normal, or shorted to low source
2117 2981 18
Amber
Coolant pressure Coolant pressure 2 data valid but below
normal operational range moderately
severe level
386 3509 3 Amber 5 volts dc supply
Sensor supply voltage #1 circuit voltage
above normal, or shorted to high source
352 3509
4 Amber 5 volts dc supply
Sensor supply voltage #1 circuit voltage
below normal, or shorted to low source
227 3510 3 Amber 5 volts dc supply
Sensor supply voltage #2 circuit voltage
above normal, or shorted to high source
187 3510
4 Amber 5 volts dc supply
Sensor supply voltage #2 circuit voltage
below normal, or shorted to low source
239 3511 3 Amber
System diagnostic
code #2
Sensor supply voltage #3 circuit voltage
above normal, or shorted to high source
238 3511 4 Amber
System diagnostic
code #1
Sensor supply voltage #3 circuit voltage
below normal, or shorted to low source
REFERENCE
67. The descriptions of Cummins J1939 SPN codes are subject to change at their discretion.